Configure cross zoning on a 2GIG GoControl
print icon

On the 2GIG GoControl, zones 47 and 48 can be configured to be cross zones.

Cross zoning helps with false alarm reduction and unnecessary police dispatches. Typically, cross zoning is used with a motion sensor in a high traffic area combined with either a second motion sensor or a contact sensor nearby. This setup allows it so that if the motion sensor detected a non-human motion event and triggered a false alarm, the monitoring station would not dispatch. If the door or window opened and the motion sensor activated within the same minute or 2, it is more likely a real alarm. 

For example: 

  • If one zone (with cross zoning enabled on zone attributes) is activated, it will not send an alarm to the monitoring station, but if both zones (that have cross zoning enabled) are activated before the cross zone timer expires, it will trigger an alarm.
  • If this second zone is not triggered during the cross zone timer period, the event Cross Zone Not Verified is sent to the monitoring station, letting them know that one zone tripped but not both. This is a non-alarm event forwarded to the monitoring station.

Note: CO and Fire Zones cannot be used in zones 47 and 48 as cross zones. 

To configure cross zoning on a 2GIG GoControl using the keypad:

  1. Tap Security.
  2. Tap Menu.
  3. Tap Toolbox.
  4. Enter the installer code.
  5. In the Toolbox, tap  to scroll to Installer Toolbox.
  6. Tap Installer Toolbox.
  7. Tap System Configuration.
  8. Tap Go to.
  9. Tap 33 to navigate to Q33: Select cross sensor 47-48 to configure zones 47 and 48 to be cross zones on the panel.
  10. Tap to enable or 0 to disable cross zoning.
  11. Tap  to navigate to Q34: Enter cross sensor timeout to configure the cross zone time.
  12. Enter the desired time in seconds.
  13. Tap End.
  14. Verify Save changes is selected, and then tap Exit.

To configure cross zoning using the Partner Portal:

Note: It is recommended to disarm the panel before making any panel programming changes.

  1. Log into the Partner Portal.
  2. Find the customer account.
  3. Click Remote Toolkit.
  4. To configure zones 47 and 48 to be cross zones on the panel:
    1. In the Command Catalog, click to expand Arming Settings.
    2. Click Q33: Select cross sensor 47-48.
    3. Using the New value dropdown menu, select either Enabled or Disabled.
    4. Click Change.
  5. To configure the cross zone time:
    1. In the Command Catalog, click to expand Timers.
    2. Click Q34: Enter cross sensor timeout.
    3. In New value, enter the desired maximum time (10-120) in seconds allowed between triggering both cross sensor zones.
    4. Click Change.

To configure cross zoning using the MobileTech app: 

Note: It is recommended to disarm the panel before making any panel programming changes. 

  1. Log into the MobileTech app.
  2. Find the customer account.
  3. Tap Remote Toolkit.
  4. Tap Command Catalog.
  5. To configure zones 47 and 48 to be cross zones on the panel:
    1. Tap to expand Arming Settings.
    2. Tap Q33: Select cross sensor 47-48.
    3. Using the New value dropdown menu, select either Enabled or Disabled.
    4. Tap Change.
  6. To configure the cross zone time:
    1. In the Command Catalog, tap to expand Timers.
    2. Tap Q34: Enter cross sensor timeout.
    3. In New value, enter the desired maximum time in seconds allowed between triggering both cross sensor zones.
    4. Tap Change.