Enable Qolsys IQ Panel 2 Panel Motion Detector

The Qolsys IQ Panel 2’s panel camera can function as a motion detector. Enabling the panel camera motion detector creates an independent zone that leverages the panel’s built-in camera to act as an activity motion detector. This falls into the zone order at the time you enable this feature. Motion can trip once every…

Remotely Find the Serial Number for an Enrolled Sensor on a Qolsys IQ Panel 2

The serial number for sensors enrolled on a Qolsys IQ Panel 2 can be found remotely using the Partner Portal or MobileTech app. For information about finding the serial number for a deleted sensor, see  Remotely find the serial number for a deleted sensor . To find the serial number of a sensor using the Partner Po…

Enable or Disable Auto Stay on a Qolsys IQ Panel 2

The auto stay feature is a way for panels to prevent false alarms. If arming locally, the customer must exit through an entry/exit sensor during the exit delay in order to have the panel arm away. Otherwise, it always reverts to arm stay. This is not the case when arming from an app or keyfob. To configure auto stay…

Clear a Severe Weather Alert from a Qolsys IQ Panel 2

Severe weather alerts to the panel notify customers of incoming dangerous weather. The alerts only come in for tornado, fire, or tsunami warnings. When an alert comes in, there is a series of audible beeps and a message on the panel. For more information about severe weather alerts, see  Severe Weather Alerts . Not…

Configure an auto phone test on a Qolsys IQ Panel 2

Auto phone tests, also called Timer or Periodic Tests, help verify that a system is communicating and that the monitoring station is receiving signals. The process is different from panel to panel, and can be programmed from different ways. If the monitoring station is not receiving auto phone tests, see  Monitoring…

Restore a Qolsys IQ Panel to a Qolsys IQ Panel 2

It is possible to back up sensor programming and user codes from a Qolsys IQ panel and restore those settings to a Qolsys IQ Panel 2. Once a Qolsys IQ panel is backed up on the Partner Portal, this can be applied to the Qolsys IQ Panel 2. Important considerations * This page outlines the procedure for restoring be…

Upgrade the Firmware on a Qolsys IQ Panel 2

The Qolsys IQ Panel 2 has the option to remotely upgrade the panel, enable automatic updates, and also perform bulk upgrades to multiple panels. Important : The update is sent through IP only, so the panel must be disarmed and connected to Wi-Fi in order to send.  Updates may take up to a few hours to apply at the p…

Enroll an Image Sensor on a Qolsys IQ Panel 2

Requirements The following are required to enroll Image Sensors to a Qolsys IQ Panel 2: * The Qolsys Image Sensor daughter card must be installed. For more information about installing the Image Sensor daughter card on the Qolsys IQ Panel 2, see  Qolsys IQ Panel 2 Image Sensor IQ Card Installation . * The custome…

How many digits can be in a system user code on the Qolsys IQ Panel 2?

The Qolsys IQ Panel 2 on firmware version 2.3.0+ can be set to have either 4-digit or 6-digit user codes. On firmware versions below 2.3.0, the Qolsys IQ Panel 2 can only have 4-digit user codes. Enable/disable 6 digit user codes The number of digits in a user code can be enabled or disabled using the Partner Port…

Manage Z-Wave devices on a Qolsys IQ Panel 2

The Z-Wave controller on the Qolsys IQ Panel 2 is in the panel itself, so swapping the panel requires the deletion and addition of existing Z-Wave devices. The local Z-Wave control available by default, so there is no need to enable a specific setting to communicate through Z-Wave. For a full list of compatible Z-Wa…