Unlike the Qolsys IQ Panel 2, the IQ Panel 2 Plus includes a built-in PowerG daughtercard. Since the PowerG daughtercard uses the same antenna as the Image Sensor daughtercard, the IQ Panel 2 Plus is not compatible with the Image Sensor. The Qolsys IQ Panel 2 and 2 Plus are both compatible with the PowerG PIR camera…
The Qolsys IQ Panel 2 has the ability to run Alarm.com Scenes locally at the panel. For more information about configuring Scenes, see Create/edit a Scene . Compatibility To following are required to locally run Scenes. * The Qolsys IQ Panel 2 must be on firmware version 2.4.0+. * Local Scenes support must be e…
Enterprise Notices allow dealers to send messages to be displayed locally at the panel. There are multiple default messages to choose from that can be sent to the panel. This feature does not allow personalized messages to be sent to the panel. Currently, the messages are only available in English. To send a message…
Compatibility * On panel firmware version below 2.3.0, the Qolsys IQ Panel 2 supports one partition. * On panel firmware version 2.3.0+, the Qolsys IQ Panel 2 supports up to four partitions. For more information about updating the panel firmware remotely, see Upgrade the firmware on a Qolsys IQ Panel 2 . Remotel…
Requirements The following are required to enroll Image Sensors to a Qolsys IQ Panel 2: * The Qolsys Image Sensor daughter card must be installed. For more information about installing the Image Sensor daughter card on the Qolsys IQ Panel 2, see Qolsys IQ Panel 2 Image Sensor IQ Card Installation . * The custome…
Bluetooth Low Energy (BLE) 4.0 is built into the IQ Panel 2. The Qolsys IQ Panel 2 allows for up to five mobile Bluetooth devices to be paired with the panel. Pairing mobile Bluetooth devices allow for Bluetooth disarm, which disarms the system from an armed away state when the connected mobile device comes within ra…
Sending a communication test from the panel initiates communication and verifies that the module is communicating on the cellular network. For this test to send a signal to the monitoring station, verify Manual/Auto Tests are selected as an Event to Forward in the customer's Monitoring Settings . For more info…
The Qolsys IQ Panel 2 is compatible with Dual-Path Wi-Fi communication. The panel can be connected to a Wi-Fi network using the panel, Partner Portal, or MobileTech app. Note : A communication test must be performed to initially register the cellular module before a Wi-Fi or Dual-Path test is performed. If a communi…
Measuring panel voltage is a common troubleshooting step when experiencing odd behavior on a panel. Most often, this step is required when there is a Modem-Panel Comm message, or the panel is not communicating properly with Alarm.com. If the voltage drops low, a modem-panel communication trouble may occur. Voltage…
On the Qolsys IQ Panel 2, it is possible to bypass an open contact sensor, or any sensor with a trouble condition (e.g., tamper, low battery, offline, etc.) when arming a system from the Customer Website or app. Simply sending an arming command will automatically bypass all zones that would prevent arming. A motion s…