You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.

Showing articles from 2GIG GC3 tag

2GIG GC3 - Monitoring Station Dialer Codes

Monitoring Station dialer codes are led with either a  1  or  E  to indicate the event signal, and led with a  3  or  R  to indicate a restore signal. The event history on Alarm.com always displays the codes leading with a  1  to indicate the event and  3  to indicate the restore. Reporting Zones 2GIG Type De…

Bypass a sensor on a 2GIG GC3

On the 2GIG GC3 panel, it is possible to bypass an open contact sensor, or any sensor with a trouble condition (e.g., tamper, low battery, offline, etc.) when arming a system from the customer website or mobile app. When sending an arming command, the system automatically bypasses the sensor if  Q20: Keyfob/remote a…

Enroll an Image Sensor on a 2GIG GC3

Requirements The following are required to enroll Image Sensors to a 2GIG GC3 panel: * A customer account has been created on Alarm.com with a service package that includes an  Images  add-on. * The Alarm.com module and XCVR3 transceiver are installed properly in the panel. For more information about installing t…

2GIG GC3 Image Sensor (2GIG-IMAGE2) - Installation Guide

Product overview The Image Sensor for 2GIG GC3 panels is a pet immune PIR (passive infrared) motion detector with a built-in camera. The sensor is designed to capture images during alarm or non-alarm events. Users can also initiate image capture on-demand to Peek-In on their property. Images are stored locally and …

How do multiple partitions work with the 2GIG GC3?

Compatibility On panel firmware version below 3.2, the 2GIG GC3 supports one partition. On panel firmware version 3.2+, the 2GIG GC3 supports up to four partitions. Partitions are also referred to as Smart Areas on the 2GIG GC3. Note : To upgrade to 3.2.0, the panel firmware version must be 3.1.3+. For more inform…

2GIG GC3 - Two-Way Voice Installation Guide

The 2GIG GC3 supports Two-Way Voice. This gives the 2GIG GC3 Panel’s cellular radio module the ability to automatically dial the monitoring station and connect with an operator after an alarm sounds. Once connected with the monitoring station, people on the premises can communicate with the operator using the 2GIG GC…

Clear a panel tamper on a 2GIG GC3

When a panel tamper occurs on a 2GIG GC3, it locally displays  Console Tamper  and the trouble condition appears on Alarm.com. The tamper switch on a 2GIG GC3 is the white plastic rectangle on the bottom of the panel near the 2GIG WLAN chip. How to resolve: * Affix the backplate onto the panel and verify the wh…

2GIG GC3 Image Sensor (ADC-IS-300-LP) - Installation Guide

Product summary & technical specifications The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in camera designed to capture images during alarm or non-alarm events when motion is detected. Product features: * Communicates wirelessly to the security control panel * 35 foot de…

Disable trouble beeps on a 2GIG GC3

There is no way to indefinitely disable trouble beeps at all times for the 2GIG GC3 panel. Trouble beeps include beeps caused by AC power loss, system low battery, sensor low battery or RF supervision, failure to communicate with the Monitoring Station, control panel tampering while disarmed, and cell radio faults. …

2GIG GC3 - Equipment Codes

Required for all wireless zones, keyfobs, and keypads. For information on the loop number to program, refer to the device's installation manual. Wireless Zones - Equipment Codes Equipment Code Description 0000 Other 0862 2GIG Thin D/W (Surface) Contact 0863 2GIG Recessed Door Contact 0869 2GIG PIR wi…